| Model Number |
24S025 |
24S050 |
24S088
|
24S200 |
| |
| Performance |
| Nominal Tonnage |
Ton |
1/4 |
1/2 |
1 |
2 |
| Nominal Compressor |
HP |
1/3 |
1/2 |
1 |
2.5 |
| Net Cooling Capacity* |
| @80 Deg F condenser inlet water |
BTUH |
3000/3300 |
5300/5700 |
7800/8450 |
15200/16550 |
| Controls |
| Type |
Room mounted non-programmable thermostat |
| Accuracy |
± 2°F |
| Evaporator Section |
| Fan Motor Size |
Watts |
75 |
100 |
195 |
240 |
| Air Flow |
CFM |
235 |
430 |
510 |
740 |
| Air Flow with 25’ flex duct |
CFM |
207 |
400 |
485 |
715 |
| Water Cooled Condenser Section |
| Water usage at 40 Deg F rise |
GPM |
0.30 |
0.60 |
1.20 |
2.50 |
| Pressure drop |
PSI |
0.40 |
0.40 |
0.85 |
1.20 |
| Pipe connection size (in/out) |
Inches |
0.50 |
0.50 |
0.50 |
0.63 |
| Heat |
| Type |
Integral electric heater coil |
| Capacity |
Watt / BTUH |
1000 / 3413 |
1000 / 3413 |
2000 / 6826 |
2000 / 6826 |
| Temperature rise - including fan |
Deg° F |
13.5 |
8.6 |
12 |
8.1 |
| Humidifier |
| Type |
|
Removable drip pad with integral fan |
| Supply water temp of 60 Deg F |
gal./day |
1.6 |
| Supply water temp of 90 Deg F |
gal./day |
3.5 |
| Supply water temp of 120 Deg F |
gal./day |
5.1 |
| Control |
|
Cellar mounted digital humidistat |
| Electrical Requirements |
| Power Requirements |
V/P/H |
115/1/60 |
115/1/60 |
230/1/60 |
230/1/60 |
| Current Draw - Cooling mode |
Amps |
8.6 |
11.9 |
9.0 |
16 |
| Current Draw - Heating mode |
Amps |
9.4 |
9.6 |
9.6 |
10 |
| Minimum Circuit Size |
Amps |
15 |
15 |
15 |
20 |
| Optional Low Ambient |
Amps |
0.4 |
0.4 |
0.2 |
0.2 |
| Optional Humidifier |
Amps |
0.3 |
0.3 |
0.2 |
0.2 |
| Typical Testing Data (Factory) |
| Head Pressure |
psig |
159 |
140 |
140 |
138 |
| Suction Pressure |
psig |
40 |
30 |
25 |
27 |
| Evaporator Inlet Temperature |
Deg F |
56 |
55 |
57 |
55 |
| Evaporator Outlet Temperature |
Deg F |
44 |
44 |
43 |
46 |
| Condenser Inlet Temperature |
Deg F |
80 |
80 |
80 |
80 |
| Condenser Outlet Temperature |
Deg F |
120 |
120 |
120 |
120 |
| Agency Approval(s) |
ETL - Conforms to UL Std. 1995, Can/CSA C22.2 No 236 |
| 1. Net cooling capacity @ cellar temp. & humidity of 55° F & 60 % RH / 60° F & 60% RH and at rated airflow. Reduce capacity by 3% for each 10% reduction in evaporator airflow. |
| 2. Vigilant, Inc. reserves the right to make changes to this document without prior notice at its sole discretion. |
| 3. All ratings recorded at sea level. |